INPUT & OUTPUTPHYSICAL SPECIFICATIONS
Nominal Input Voltage & Frequency120 VAC, 50 / 60 Hz (Default) ; 230 VAC, 50 / 60Hz (Internal jumper setting)LED DisplayGreen LED: Half Power Mode is selected
AC Input Current(i) At 120 VAC: 15.3A, (ii) At 230 VAC: 8.3AAnalogue MeterAmmeter: 0 to 80A ; Voltmeter: 0-30 VDC
AC Input ConnectionAttached Power Cord: 6 ft length ; 3 x AWG#12 wire size ; NEMA5-20P PlugType of CoolingSwitch on when charging current rises to 8A ± 1A; Switch off when charging
current drops to 4A ± 0.5A ; Switch on when Power Transformer temperature
rises to 105 ± 5°C/ 221 ± 9°F
Charging Current40A (Full Power Bulk Stage Current) ; 20A (Half Power Bulk Stage Current)L x W x H31 x 244 x 97 mm / 13.03 x 9.61 x 3.82 in
Charging Stages3 Stages (DIP Switch setting – Default): Bulk, Absorption and Float
2 Stages (DIP Switch setting): Bulk and Float
Weight9.0lb / 4.1kg
Charging VoltagesBulk Stage: 27.0 VDC
Absorption: 28.8 VDC (Default) ; 28.0 VDC (DIP Switch setting) ;
Disable (DIP Switch setting)
Float: 27.0 VDC
No. of Charging Banks2
Output ConnectionsTubular Hole with Set Screw ; Hole Diameter: 7.9 mm ; 5/16 in ; Set Screw Size
5/16” x 24 TPI
FUSESPROTECTION
Internal AC Input Side Fuse (120vac)20A, 250V; Size 6.3mm x 32mm; Time Delay Type Mfr.: Littelfuse 0325020 or equivalentOutput Short CircuitNo output voltage. Manual reset
Internal AC Input Side Fuse (230vac)20A, 250V; Size 6.3mm x 32mm; Time Delay Type Mfr.: Littelfuse 0325020 or equivalentInput Overload20A input side fuse will blow (120 VAC input)
Internal DC Output Side Fuse45A [3 x (32V, 15A) in parallel]; Automotive Blade Type; Fast Acting
Mfr.: Littelfuse 0287015 or equivalent
Output OverloadElectronic current limit at 80A (Full Power Mode) / 40±1A (Half Power Mode)
Reverse Polarity on Output Side3 x 15A output side fuses will blow
Over Temperature ShutdownPower Transformer temperature rises to 105°C ±5°C / 221°F ±9°F. Manual reset.

 

 

ENVIRONEMNTCOMPLIANCE
Operating Temperature Range-20°C to +40°C / -4°F to +104SafetyConforms to UL STD. 1564
Storage Temperature-30°C to +70°C / -22°F to +158°FCertified to CSA STD. C22.2 No. 107.2
Relative HumidityUp to 90%, non condensingEmiFCC Part 15(B), Class B
Operating ConditionIndoor, Ventilated, Cool and Dust Free
Weight9.04 lbs
Dimensions13.03 × 9.61 × 3.82 in