| Series | 5000 | Warranty | 5 Years |
|---|---|---|---|
| Volts | 8 | BCI | SPEC |
| Cells | 4 | Plates/Cell | 23 |
| Terminal Type | Flag RR | ||
| Charge | |
|---|---|
| Charge Voltage Range | 2.45-2.5 V/cell @ 25°C (77°F) |
| Float Voltage Range | 2.25 V/cell @ 25°C (77°F) |
| Self-Discharge Rate | 5%-10% per month at 25°C (77°F) |
| Capacity | |
|---|---|
| Cold Crank Amps (CCA) 0°F / -18°C | 1559 |
| Marine Crank Amps (MCA) 32°F / 0°C | 1949 |
| Reserve Capacity (RC @ 25A) | 1123 Minutes |
| Reserve Capacity (RC @ 75A) | 374 Minutes |
| Capacity Affect by Temperature | 40°C (104°F) | 25°C (77°F) | 0°C (32°F) | -15°C (5°F) |
|---|---|---|---|---|
| 105% | 100% | 75% | 50% |
| Hour Rate | Capacity / AMP Hour | Current / AMPs |
|---|---|---|
| @ 100 Hour Rate | 538 AH | 5.38 A |
| @ 72 Hour Rate | 524 AH | 7.28 A |
| @ 50 Hour Rate | 505 AH | 10.11 A |
| @ 20 Hour Rate | 468 AH | 23.40 A |
| @ 15 Hour Rate | 440 AH | 29.33 A |
| @ 10 Hour Rate | 421 AH | 42.12 A |
| @ 8 Hour Rate | 402 AH | 50.31 A |
| @ 5 Hour Rate | 374 AH | 74.88 A |
| @ 1 Hour Rate | 220 AH | 219.96 A |
| Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F). Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250. | ||
| Specifications | |||
|---|---|---|---|
| Weight | 109.5 kg | 241.5 lbs | |
| Length | 71.8 cm | 28.25“ | |
| Width | 21 cm | 8.25“ | |
| Height Inc. Term. | 46.4 cm | 18.25“ | |
| Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components. | |||
| Electrolyte Reserve | 143 mm | 5.63“ | |
| Container (Inner) | Polypropylene | ||
| Cover (Inner) | Polypropylene – heat sealed to inner container | ||
| Container (Outer) | High Density Polyethylene | ||
| Cover (Outer) | High Density Polyethylene snap fit to outer container | ||
| Handles | Molded | ||
Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration













There are no reviews yet.