INPUT & OUTPUT | PHYSICAL SPECIFICATIONS | ||
Nominal Input Voltage & Frequency | 120 VAC, 50 / 60 Hz (Default) ; 230 VAC, 50 / 60Hz (Internal jumper setting) | LED Display | Green LED: Half Power Mode is selected |
AC Input Current | (i) At 120 VAC: 10.1A, (ii) At 230 VAC: 5.5A | Analogue Meter | Ammeter: 0 to 30A ; Voltmeter: 0-30 VDC |
AC Input Connection | Attached Power Cord: 6 ft length ; 3 x 16AWG wire size ; NEMA5-15P Plug | Type of Cooling | Switch on when charging current rises to 6A ± 1A; Switch off when charging current drops to 3A ± 0.5A ; Switch on when Power Transformer temperature rises to 105 ± 5°C/ 221 ± 9°F |
Charging Current | 25A (Full Power Bulk Stage Current) ; 12.5A (Half Power Bulk Stage Current) | L x W x H | 331 x 244 x 97 mm / 13.03 x 9.61 x 3.82 in |
Charging Stages | 3 Stages (DIP Switch setting – Default): Bulk, Absorption and Float 2 Stages (DIP Switch setting): Bulk and Float |
Weight | 9.0lb / 4.1kg |
Charging Voltages | Bulk Stage: 27.0 VDC Absorption: 28.8 VDC (Default) ; 28.0 VDC (DIP Switch setting) ; Disable (DIP Switch setting) Float: 27.0 VDC |
||
No. of Charging Banks | 2 | ||
Output Connections | Tubular Hole with Set Screw ; Hole Diameter: 7.9 mm ; 5/16 in ; Set Screw Size 5/16” x 24 TPI |
FUSES | PROTECTION | ||
Internal AC Input Side Fuse (120vac) | 12A, 250V; Size 6.3mm x 32mm; Time Delay Type Mfr.: Littelfuse 0218008 or equivalent |
Output Short Circuit | No output voltage. Manual reset |
Internal AC Input Side Fuse (230vac) | 40A [2 x (32V, 20A) in parallel]; Automotive Blade Type; Fast Acting Mfr.: Littelfuse 0287030 or equivalent |
Input Overload | 12A input side fuse will blow (120 VAC input) |
Output Overload | Electronic current limit at 25A (Full Power Mode) / 12.5±1A (Half Power Mode) | ||
Reverse Polarity on Output Side | 2 x 20A output side fuses will blow | ||
Over Temperature Shutdown | Power Transformer temperature rises to 105°C ±5°C / 221°F ±9°F. Manual reset. |
There are no reviews yet.