GENERAL DATA
Dimension / b | 429 mm |
|---|---|
Dimension / h | 627 mm |
| Weight | 21,5 kg |
| Dimension (width) | 429 mm |
| Dimension (height) | 627 mm |
| Dimension (depth) | 206 mm |
| Weight | 21,5 kg |
| Protection class | NEMA 4X |
| Night time consumption | < 1 W |
| Inverter topology | Transformerless |
| Cooling | Variable speed fan |
| Elevation | 4000 m (13120 ft) with a max. input voltage of 1000 V |
| Certificates and compliance with standards | UL 1741-2010 Second Edition (incl. UL1741 Supplement SA 2016-09 for California Rule 21 and Hawaiian Electric Code Rule 14H), UL1998 (for functions: AFCI, RCMU and isolation monitoring), IEEE 1547-2003, IEEE 1547.1-2003, ANSI/IEEE C62.41, FCC Part 15 A & B, NEC 2017 Article 690, C22. 2 No. 107.1-16, UL1699B Issue 2 -2013, CSA TIL M-07 Issue 1 – 2013 |
| DC connection terminals | 4x DC+ and 4x DC- screw terminals for copper (solid/stranded/fine stranded) or aluminium (solid/stranded) |
| AC connection terminals | Screw terminals 12 – 6 AWG |
| Revenue Grade Metering | Optional (ANSI C12.1 accuracy) |
| UL safety standards & network regulations | UL 1741-2010, UL 1998, UL 1699B Issue 2-2013 |
INPUT DATA
| Number of MPPT | 2 |
|---|---|
| Recommended PV Power (kWp) | 4,8 – 9,3 kWp |
| Max. usable input current | 18,0 / 18,0 A |
Max. usable input current total (MPPT1 + MPPT2) | 36 A |
Max. array short circuit current (1.5 * Imax) | 27 / 27 A |
Nominal input voltage | 420 V |
| Operating voltage range | 80 – 1000 V |
MPP Voltage Range | 240 – 800 V |
Max. input voltage (Udc max) | 1000 V |
OUTPUT DATA
| Max. output power 240 V | 6000 VA |
|---|---|
| Max. output power 208 V | 6000 VA |
Output configuration | 1~ NPE 208 / 240 V |
| Frequency range | 45 – 66 Hz |
| Nominal operating frequency | 60 Hz |
| Total harmonic distortion | < 5 % |
Power factor range | 0,85 – 1 ind,/cap, |
| Max. continuous output current 240 V | 25,0 A |
| Max. continuous output current 208 V | 28,8 A |
| OCPD/AC breaker size 208 V | 40 A |
| Max. efficiency | 96,9 % |
| CEC efficiency 240 V | 96,0 % |
| CEC efficiency 208 V | 96,0 % |
PROTECTION DEVICES
| DC reverse polarity protection | Yes |
|---|---|
| Anti islanding | internal; in accordance with UL 1741-2016-09, IEEE 1547-2003 and NEC 2017 |
| Over temperature protection | Output power derating / Active cooling |
| AFCI | Yes |
| Rapid shutdown compliant | Yes (according to NEC 2014) |
| Ground fault protection with isolation monitor interrupter | Yes |
| DC disconnect | Yes |
INTERFACES
| USB (A socket) | Datalogging and inverter update possible via USB |
|---|---|
| 2x RS422 (RJ45 socket) | Fronius Solar Net |
| Wi-Fi / Ethernet / Serial / Datalogger and webserver (optional) | Wireless standard 802.1 1 b/g/n / Fronius Solar.web, SunSpec Modbus TCP, JSON / SunSpec Modubs RTU |
| 6 inputs or 4 digital inputs/outputs (optional) | Load management; signaling, multipurpose I/O |












There are no reviews yet.