| Series | FLA SERIES 4000 | Warranty | 3 Years |
|---|---|---|---|
| Volts | 2 | Design | L16 |
| Cells | 1 | Plates/Cell | 53 |
| Terminal Type | LT | ||
| Included Hardware | S/S Hex Cap Screw, Nut, Lock & Flat Washer | ||
| Size & Thread | 5/16″-18 | ||
| Cables | Optional: 19″ 4/0 interconnect cable | ||
| Charge | Discharge | |
|---|---|
| Charge Voltage Range | 2.45-2.5 V/cell @ 25°C (77°F) |
| Float Voltage Range | 2.25 V/cell @ 25°C (77°F) |
| Recommended Charge Current | 175 A |
| Maximum Charge Current | 290 A |
| Self-Discharge Rate | 5%-10% per month at 25°C (77°F) |
| Capacity | |
|---|---|
| Cold Crank Amps (CCA) 0°F / -18°C | 3378 |
| Marine Crank Amps (MCA) 32°F / 0°C | 4223 |
| Reserve Capacity (RC @ 25A) | 2909 Minutes |
| Reserve Capacity (RC @ 75A) | 764 Minutes |
| Capacity Affect by Temperature | 40°C (104°F) | 25°C (77°F) | 0°C (32°F) | -15°C (5°F) |
|---|---|---|---|---|
| 105% | 100% | 75% | 50% |
| Hour Rate | Capacity / AMP Hour | Current / AMPs |
|---|---|---|
| @ 100 Hour Rate | 1728 AH | 17.28 A |
| @ 72 Hour Rate | 1683 AH | 23.38 A |
| @ 50 Hour Rate | 1623 AH | 32.46 A |
| @ 20 Hour Rate | 1503 AH | 75.15 A |
| @ 15 Hour Rate | 1413 AH | 94.19 A |
| @ 10 Hour Rate | 1353 AH | 135.27 A |
| @ 8 Hour Rate | 1293 AH | 161.57 A |
| @ 5 Hour Rate | 1202 AH | 240.48 A |
| @ 1 Hour Rate | 706 AH | 706.41 A |
| Specifications | |||
|---|---|---|---|
| Weight | 59 kg | 130 lbs | |
| Length | 318 mm | 12.5“ | |
| Width | 181 mm | 7.13“ | |
| Height Incl. Term. | 432 mm | 17“ | |
| Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components. | |||
| Electrolyte Reserve | 57 mm | 2.25“ | |
|---|---|---|---|
| Container | High Density Polypropylene | ||
| Cover | High Density Polypropylene | ||
| Handles | Rope / Plastic Handle | ||
| |||
Cycle Life vs. Depth of Discharge

Voltage vs. Depth of Discharge

Detailed Illustration