Series | 5000 | Warranty | 5 Years |
---|---|---|---|
Volts | 2 | BCI | SPEC |
Cells | 2 | Plates/Cell | 31 |
Terminal Type | Flag | ||
Included Hardware | S/S Hex Cap Screw, Nut, Lock & Flat Washer | ||
Size & Thread | 5/16″-18 | ||
Cables | 19″ 4/0 interconnect cables *RE incl. |
Charge | |
---|---|
Charge Voltage Range | 2.45-2.5 V/cell @ 25°C (77°F) |
Float Voltage Range | 2.25 V/cell @ 25°C (77°F) |
Self-Discharge Rate | 5%-10% per month at 25°C (77°F) |
Capacity | |
---|---|
Cold Crank Amps (CCA) 0°F / -18°C | 11482 |
Marine Crank Amps (MCA) 32°F / 0°C | 14352 |
Reserve Capacity (RC @ 25A) | 12131 Minutes |
Reserve Capacity (RC @ 75A) | 4044 Minutes |
Capacity Affect by Temperature | 40°C (104°F) |
25°C (77°F) |
0°C (32°F) |
-15°C (5°F) |
---|---|---|---|---|
105% | 100% | 75% | 50% |
Hour Rate | Capacity / AMP Hour | Current / AMPs |
---|---|---|
@ 100 Hour Rate | 6520 AH | 65.20 A |
@ 72 Hour Rate | 6166 AH | 85.64 A |
@ 50 Hour Rate | 5838 AH | 116.76 A |
@ 20 Hour Rate | 5054 AH | 252.72 A |
@ 15 Hour Rate | 4701 AH | 313.37 A |
@ 10 Hour Rate | 4498 AH | 449.84 A |
@ 8 Hour Rate | 4347 AH | 543.35 A |
@ 5 Hour Rate | 4044 AH | 808.70 A |
@ 1 Hour Rate | 2274 AH | 2274.48 A |
Ampere hour capacity ratings based on specific gravity of 1.280 at 27°C (80°F). Reduce capacities 5% for specific gravity of 1.265 and 10% for 1.250. |
Specifications | |||
---|---|---|---|
Weight | 258.5 kg | 570 lbs | |
Length | 69.5 cm | 27.38“ | |
Width | 26.7 cm | 10.5“ | |
Height Inc. Term. | 80.3 cm | 31.63“ | |
Product measurements & weights are calculated based on sample data. Individual specifications are subject to vary due to the manufacturing process & battery components. |
Electrolyte Reserve | 95 mm | 3.75“ | |
---|---|---|---|
Container (Inner) | Polypropylene | ||
Cover (Inner) | Polypropylene – heat sealed to inner container | ||
Container (Outer) | High Density Polyethylene | ||
Cover (Outer) | High Density Polyethylene snap fit to outer container | ||
Handles | Molded |
There are no reviews yet.