Fluke 726 Offers
Get More Calibration Power
The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind.
The Fluke 726 measures and sources almost all process parameters and can calibrate almost anything. Also, the Fluke 726 will interpret results without the help of a calculator and store measurement data for later analysis.Fluke 726 Offers
Get More Calibration Power
The Fluke 726 Precision Multifunction Process Calibrator is designed specifically for the Process industry with broad workload coverage, calibration power and unsurpassed accuracy in mind.
The Fluke 726 measures and sources almost all process parameters and can calibrate almost anything. Also, the Fluke 726 will interpret results without the help of a calculator and store measurement data for later analysis.
Fluke 726 Specifications
Measurement Accuracy
Voltage DC
30 V: 0.01% + 2 mV (upper display)
20 V: 0.01% + 2 mV (lower display)
90 mV: 0.01% + 10 µV
-10 to 75 mV: 0.025% + 1 count (via TC connector)
Current DC
24 mA: 0.01%+ 2 mA
Resistance
0 to 4000 Ω: ±0.015%
Frequency
2 to 1000 CPM: 0.05% + 0.1 CPM
1 to 1000 Hz: 0.05% + 0.1 Hz
1 to 15 kHz: 0.05% + 0.01 kHz
Sensitivity: 1 V peak-to-peak-minimum
Pressure
Accuracy from 0.025% of range using any of 29 pressure modules
Modules available for differential, gauge, vacuum, absolute, dual and high pressure
Source Accuracy
Voltage DC
100 mV: 0.01% + 10 µV
20 V: 0.01% + 2 mV
-10 to 75 mV: 0.025% + 1 count (via TC connector)
Current DC
24 mA (source): 0.01% + 2 µA
24 mA (simulate): 0.01% + 2 µA
Resistance
Range, accuracy (percent of reading + floor) and excitation current
5 to 400 Ω, 0.015% + 0.1 Ω, 0.1 to 0.5 mA
5 to 400 Ω, 0.015% + 0.05 Ω, 0.5 to 3 mA
400 to 1500 Ω, 0.015% + 0.5 Ω, 0.05 to 0.8 mA
1500 to 4000 Ω, 0.015% + 0.5 Ω, 0.05 to 0.4 mA
Frequency
2 to 1000 CPM: 0.05%
1 to 1000 Hz: 0.05%
1 to 10 kHz: 0.25%
10 to 15 kHz: 0.5%
Waveform: 5 V p-p squarewave, -0.1 V offset
RTDs and Thermocouples
Measure and Source Accuracy
Cu10: 1.8°C
NI-120: 0.15°C
PT-100 (385): 0.45°C
PT-100 (392): 0.35°C
PT-100 (391-JIS): 0.35°C
PT-200 (385): 0.95°C
PT-500 (385): 0.55°C
PT-1000 (385): 0.35°C
RTD resolution: 0.01°F (0.01°C)
Cu10.01 C: 0.1°F (0.1°C)
J: 0.4°C
K: 0.5°C
T: 0.4°C
E: 0.4°C
R: 1.4°C
S: 1.4°C
B: 1.4°C
L: 0.45°C
U: 0.45°C
N: 0.6°C
XK: 0.4°C
BP: 1.1°C
TC resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F
Functions
Ramp
Source functions: Voltage, current, resistance, frequency, temperature
Ramps: Slow ramp, fast ramp, 25% step-ramp
Loop Power
Voltage: 24 V
Accuracy: 10%
Maximum current: 22 mA, short circuit protected
Step
Source functions: Voltage, current, resistance, frequency, temperature
Steps: 25% of range, 100% of range
General Specifications
Environmental
Operating temperature: 14 to 131°F (-10 to 55°C)
Storage temperature: -4 to 159.8°F (-20 to 71°C)
Operating altitude: 9842.5′ (3000 m)
Agency Approvals
EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992
Battery
Type: 4 x AA alkaline batteries
Replacement: Separate battery compartment, accessible without breaking calibration seal
Side Port Connections
Pressure module connector, also used for remote real-time programming
Dimensions
7.9 x 3.8 x 1.9″ (200 x 96 x 47 mm)
Weight
23 oz (650 g)
Click here for complete specifications on the Fluke 726
What’s included with the Fluke 726
Process Calibrator
NIST-Traceable Calibration Report and Data
Test Leads
Stackable Test Leads
Alligator Clips
Quick Reference Guide
Three-Year Warranty
There are no reviews yet.