Fluke 707 Offers
The fastest, one-handed tool for loop checks.
The Fluke 707 Loop Calibrator is a high performance solution for calibration, repair and maintenance of current loops. Use it to temporarily replace the power source in a current loop. With the calibrator in control of the current, you can accurately set the current between 4 and 20 mA. This allows you to control the loop and the devices connected to it – which means you can control and calibrate actuators and indicators in that loop
Click your way to the precise milliamp value you want with Fluke 707’s “Quick Click” knob interface making it extremely fast and easy to use. Each click changes the value by 0.001 mA. Press and click to change it in increments of 0.100 mA. The large digital display shows you. The click lets you feel it.
The HART mode on the Fluke 707 connects 250 ohm resistor with 24 V loop for compatibility with HART communicators.
For the intrinsically safe version – look at the Fluke 707Ex Intrinsically Safe Loop Calibrator
For a lower price – look at the Fluke 705 Loop Calibrator
Also, see the Fluke 715 Volt/mA CalibratorFluke 707 Offers
The fastest, one-handed tool for loop checks.
The Fluke 707 Loop Calibrator is a high performance solution for calibration, repair and maintenance of current loops. Use it to temporarily replace the power source in a current loop. With the calibrator in control of the current, you can accurately set the current between 4 and 20 mA. This allows you to control the loop and the devices connected to it – which means you can control and calibrate actuators and indicators in that loop
Click your way to the precise milliamp value you want with Fluke 707’s “Quick Click” knob interface making it extremely fast and easy to use. Each click changes the value by 0.001 mA. Press and click to change it in increments of 0.100 mA. The large digital display shows you. The click lets you feel it.
The HART mode on the Fluke 707 connects 250 ohm resistor with 24 V loop for compatibility with HART communicators.
For the intrinsically safe version – look at the Fluke 707Ex Intrinsically Safe Loop Calibrator
For a lower price – look at the Fluke 705 Loop Calibrator
Also, see the Fluke 715 Volt/mA Calibrator
Fluke 707 Specifications
Current Measurement
Range: 0 to 24 mA, Resolution: 0.001 mA, Accuracy: 0.015% Rdg + 2 LSD
Current Sourcing
Range: 0 to 20 mA or 4 to 20 mA, Accuracy: 0.015% Rdg + 2 LSD, Drive Capability: 1200 Ω; 950 Ω at 20 mA in HART mode
Current Simulation
Range: 0 to 20 mA or 4 to 20 mA, Accuracy: 0.015% Rdg + 2 LSD, Ext. loop voltage requirement: 12-30 V
Loop Power
While measuring mA, 24 V
Voltage measurement
Range: 0 to 28 V DC, Resolution: 1 mV, Accuracy: 0.015% Rdg + 2 LSD
Operating Temperature
-10 to 55°C
Humidity (Without Condensation)
0 to 90% (0 to 35°C); 0 to 70% (35 to 55°C)
Temperature Coefficient
-10 to 18°C, 28 to 55°C, ±.005% of range per °C
Safety
CSA C22.2 No. 1010.1:1992
EMC
EN50082-1:1992 and EN55022:1994 Class B
Max. Voltage
30V (protection circuit for 230V)
Size
152 x 70 x 41 mm
Weight
224 g (340 g including holster)
Batteries
One 9V battery Alkaline
Click here for complete specifications on the Fluke 707
What’s included with the Fluke 707
Fluke 707 Loop Calibrator
Fluke AC72 Alligator Clips
Fluke TL75 safety-designed test lead set
Fluke C10 protective yellow holster with Flex-Standâ„¢
Instruction sheet
There are no reviews yet.