Fluke 52-II-NIST OffersThis product includes an ISO Certificate with full Data and Uncertainties.
Features
Shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display
Features fast response and laboratory accuracy 0.05% + 0.3°C)
Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
Easy-to-access battery door that allows replacing the battery without breaking the calibration seal
Powered by 3 x standard AA batteries
Features an electronic offset function that compensates for thermocouple errors to maximize overall accuracy
Measures J, K, T, and E-type thermocouples
Handles temperatures up to 1600°F 900°C)
Presents results in °C, °F, or Kelvin K)
Provides a user-friendly front panel that is easy to set up and operate
Offers sleep mode to increase battery life; 1000-hour battery life typical
Applications
Lab
QA
Process calibration
Food safety
HVAC/R Fluke 52-II-NIST OffersThis product includes an ISO Certificate with full Data and Uncertainties.
Features
Shows any combination of T1, T2, T1-T2, plus MIN, MAX, or AVG on the large backlit dual display
Features fast response and laboratory accuracy 0.05% + 0.3°C)
Includes a relative time clock on MIN, MAX, and AVG to provide a time reference for major events
Easy-to-access battery door that allows replacing the battery without breaking the calibration seal
Powered by 3 x standard AA batteries
Features an electronic offset function that compensates for thermocouple errors to maximize overall accuracy
Measures J, K, T, and E-type thermocouples
Handles temperatures up to 1600°F 900°C)
Presents results in °C, °F, or Kelvin K)
Provides a user-friendly front panel that is easy to set up and operate
Offers sleep mode to increase battery life; 1000-hour battery life typical
Applications
Lab
QA
Process calibration
Food safety
HVAC/R
Fluke 52-II-NIST Specifications
Temperature Accuracy
Above -100°C
J, K, T, and E-type: ±[0.05% + 0.3°C]
Below -100°C
J, K, and E: ±[0.20% + 0.3°C]
Temperature
J-Type
-346 to 2192°F -210 to 1200°C)
K-Type
-328 to 2501.6°F -200 to 1372°C)
T-Type
-418 to 752°F -250 to 400°C)
E-Type
-238 to 1832°F -150 to 1000°C)
Temperature Scale
ITS-90
Applicable Standards
NIST-175
Display Resolution
0.1°C, 0.1 K <1000
1°C, 1 K ≥1000
Environmental Specifications
Operating Temperature
14 to 122°F -10 to 50°C)
Storage Temperature
-40 to 140°F -40 to 60°C)
Humidity Without Condensation)
0 to 90%; 32 to 95°F 0 to 35°C)
0 to 70%; 32 to 122°F 0 to 50°C)
Mechanical and General Specifications
Batteries
3 x batteries
Typical 1000-hour life
Dimensions
6.8 x 3.4 x 1.5" 173 x 86 x 38 mm)
Weight
0.9 lbs 400 g)
Safety Specifications
Overvoltage Category
CSA C22.2 No. 1010.1 1992; EN 61010 Amendments 1,2
Agency Approvals
CE, CSA, TÃœV pending)
Click here for complete specifications on the Fluke 52-II-NIST
What's included with the Fluke 52-II-NIST
Thermometer
ISO Certificate with full Data and Uncertainties
Holster
2 x Bead Probe Thermocouple
Three-Year Warranty
Getting to know the Fluke 52-II Dual Input Thermometer
This video will serve as an overview of the Fluke 52-II Dual Input Thermometer. Applications such as test and measurement and in facilities are great for this thermometer.