Fluke 378FC OffersUses Field-Sense™ technology to make testing faster and safer, all without touching a live conductor, and provides accurate voltage and current measurements through the clamp jaw. Easily clip the black test lead to any electrical ground, put the clamp jaw around the conductor, and see reliable, accurate voltage and current values on the display.
Features
Measure voltage and current with your clamp jaw
Faster, safer testing all without touching a live wire using FieldSense™ technology
Complete three-phase voltage and current tests in three quick steps
Power quality indicator shows whether a problem is in the equipment or the power line
This clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, it will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.
Voltage and current measurements with FieldSense™ technology
No more hand-written notes or complicated math.
Complete 3-phase voltage and current tests in three easy steps
Full set of phase-to-ground and phase-to-phase values calculated
Displayed on your smart phone and saved to the cloud via Fluke Connect software
Phase rotation calculated and shown on the Fluke Connect software
Measure extremely high current with iFlex™ probe
Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.
Easy to see, easy to use with included tools
Your job will get easier when you use this clamp meter:
The display turns green when a stable FieldSense measurement is detected
Visual Continuity provides a bright green screen for easy detection of continuity in noisy work areas
The magnetic hanging kit, with 9″ (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head
Record, analyze, share results with Fluke Connect™ software
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows
you to gather data as the basis for a preventive maintenance program.
Applications
Electrical
HVAC/R
Field service
MaintenanceFluke 378FC OffersUses Field-Sense™ technology to make testing faster and safer, all without touching a live conductor, and provides accurate voltage and current measurements through the clamp jaw. Easily clip the black test lead to any electrical ground, put the clamp jaw around the conductor, and see reliable, accurate voltage and current values on the display.
Features
Measure voltage and current with your clamp jaw
Faster, safer testing all without touching a live wire using FieldSense™ technology
Complete three-phase voltage and current tests in three quick steps
Power quality indicator shows whether a problem is in the equipment or the power line
This clamp meter includes a unique PQ function that senses power quality issues automatically. When making FieldSense measurements, it will detect and display power quality issues, relating to current, voltage, power factor or any combination of the three. Now you can quickly determine if an upstream supply problem exists, or if there is a downstream equipment problem.
Voltage and current measurements with FieldSense™ technology
No more hand-written notes or complicated math.
Complete 3-phase voltage and current tests in three easy steps
Full set of phase-to-ground and phase-to-phase values calculated
Displayed on your smart phone and saved to the cloud via Fluke Connect software
Phase rotation calculated and shown on the Fluke Connect software
Measure extremely high current with iFlex™ probe
Use the included iFlex flexible current probe to measure ac current as high as 2500 A. The iFlex probe provides access to large conductors in tight spaces.
Easy to see, easy to use with included tools
Your job will get easier when you use this clamp meter:
The display turns green when a stable FieldSense measurement is detected
Visual Continuity provides a bright green screen for easy detection of continuity in noisy work areas
The magnetic hanging kit, with 9″ (23 cm) hanging strap, lets you hang your clamp wherever you need: to a steel cabinet door; around a pipe; on a nail or screw head
Record, analyze, share results with Fluke Connect™ software
With Fluke Connect software you can remotely log, trend and monitor measurements to pinpoint intermittent faults. Fluke Connect also allows
you to gather data as the basis for a preventive maintenance program.
Applications
Electrical
HVAC/R
Field service
Maintenance
Fluke 378FC Specifications
Current
AC – Jaw
Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% ±5 digits (10 to 100 Hz); 2.5% ±5 digits (100 to 500 Hz)
Crest factor (50/60 Hz): 3 at 500 A; 2.5 at 600 A; 1.42 at 1000 A; Add 2% for C.F. >2
AC – Flexible Current Probe
Range: 2500 A
Resolution: 1 A (≤2500 A) 0.1 A (≤999.9 A)
Accuracy: 3% ±5 digits (5 to 500 Hz)
DC
Range: 999.9 A
Resolution: 0.1 A
Accuracy: 2% ±5 digits
Voltage
AC – FieldSense
Range: 1000 V
Resolution: 1 V (≤1000 V)
Accuracy: ≤4/0 AWG – 3% ±5 digits (45 to 66 Hz); ≥4/0 AWG – 5% ±5 digits (45 to 66 Hz)
AC – Test Leads
Range: 600.0 V, 1000 V
Resolution: 0.1 V (≤600.0 V); 1 V (≤1000 V)
Accuracy: 1% ±5 digits (20 to 500 Hz)
DC
Range: 600 V, 1000 V
Resolution: 0.1 V (≤600 V); 1 V (≤1000 V)
Accuracy: 1% ± 5 digits
mV DC
Range: 500 mV
Resolution: 0.1 mV
Accuracy: 1% ±5 digits
Amps Frequency
Jaw
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% ±5 digits
Trigger level: 5 to 10 Hz, ≥10 A; 10 to 100 Hz, ≥5 A; 100 to 500 Hz, ≥10 A
Flexible Current Probe
Range: 5 to 500 Hz
Resolution: 0.1 Hz
Accuracy: 0.5% ±5 digits
Trigger level: 5 to 20 Hz, ≥25 A; 20 to 100 Hz, ≥20 A; 100 to 500 Hz, ≥25 A
Other Measurements
Resistance
Range: 60 kΩ, 6000 Ω, 600 Ω
Resolution: 0.1 Ω (≤600 Ω), 1 Ω (≤6000 Ω), 10 Ω (≤60 kΩ)
Accuracy: 1% ±5 digits
Capacitance
Range: 1000 μF
Resolution: 0.1 μF (≤100 μF), 1 F (≤1000 μF)
Accuracy: 1% ±4 digits
General Specifications
General Maximum Voltage
1000 V (between any terminal and earth ground)
Battery
Type: 2 x AA IEC LR6 alkaline
life: 200 hours
Display
Dual readout
Automatic Power Off
20 minutes
Temperature
Operating: 14 to 122°F (-10 to 50°C)
Storage: -40 to 140°F (-40 to 60°C)
Operating Humidity (Without Condensation)
Non condensing (<50°F [<10°C])
≤90% RH (50 to 86°F [10 to 30°C])
≤75% RH (86 to 104°F [30 to 40°C])
≤45% RH (104 to 122°F [40 to 50°C])
Temperature Coefficients
Add 0.1 x specified accuracy for each degree C >28°C or <18°C
Ingress Protection
IEC 60529: IP30 (jaw closed)
Altitute
Operating: 6561.68' (2000 m)
Storage: 39,370.1' (12,000 m)
Electromagnetic Compatibility (EMC)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Safety
General: IEC 61010-1: Pollution degree 2
Measurement: IEC 61010-2-032: CAT III 1000 V/CAT IV 600 V; IEC 61010-2-033: CAT III 1000 V/CAT IV 600 V
Wireless Radio
Radio frequency certification: FCC ID: T68-FBLE IC:6627A-FBLE
Frequency range: 2405 to 2480 MHz
Output power: <100 mW
Dimensions
10.78 x 3.38 x 1.85" (274 x 86 x 47 mm)
Jaw opening: 1.34" (34 mm)
Flexible current probe diameter: 0.29" (7.5 mm)
Flexible current probe cable length: 5.9' (1.8 m)
Rogowski coil length: 17.71" (450 mm)
Weight
1 lbs (463 g) with batteries
Click here for complete specifications on the Fluke 378FC
What's included with the Fluke 378FC
Clamp Meter
Flexible Probe
ToolPak™ Magnetic Meter Hanger
Test Leads
TwistGuard™ Test Probes
Black Grounding Clip
Premium Carrying Case
Quick Reference Guide
Webinar: EVSE Safety Maintenance with Fluke
In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.