Fluke 1587-MDT FC Offers
FLUKE 1587 FC Insulation Tester
PI/DAR timed ratio tests (1587 FC only)
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
VFD low-pass filter for accurate motor drive measurements (1587Â FC only)
Auto-discharge of capacitive voltage for added user protection
Insulation test (1587 FC: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to 600 MΩ)
Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V),(1577: 500 V, 1000 V) for many applications
AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
Capacitance, diode test, temperature, Min/Max, frequency (Hz)(1587 FC only)
Auto power off to save battery power
CAT III 1000 V, CAT IV 600 V measurement category
Rugged, utility hard case allows you to bring everything you need for the job
Large display with backlight
FLUKE i400 AC Current Clamp
Companion to your DMM to measure up to 400 A AC
1mA/Amp output guarantees easy reading on you meter
Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
Specially designed to offer maximum utility in a very compact shape
FLUKE 9040 Phase Rotation Indicator
3 phase indication
Indication of phase rotation
Clear LCD display
No battery requiredFluke 1587-MDT FC Offers
FLUKE 1587 FC Insulation Tester
PI/DAR timed ratio tests (1587 FC only)
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
VFD low-pass filter for accurate motor drive measurements (1587Â FC only)
Auto-discharge of capacitive voltage for added user protection
Insulation test (1587 FC: 0.01 MΩ to 2 GΩ) (1577: 0.1 MΩ to 600 MΩ)
Insulation test voltages (1587 FC: 50 V, 100 V, 250 V, 500 V, 1000 V),(1577: 500 V, 1000 V) for many applications
AC/DC voltage, DC millivolts, AC/DC milliamps, Resistance (Ω), Continuity
Capacitance, diode test, temperature, Min/Max, frequency (Hz)(1587 FC only)
Auto power off to save battery power
CAT III 1000 V, CAT IV 600 V measurement category
Rugged, utility hard case allows you to bring everything you need for the job
Large display with backlight
FLUKE i400 AC Current Clamp
Companion to your DMM to measure up to 400 A AC
1mA/Amp output guarantees easy reading on you meter
Only current clamp available with a CAT IV 600 V / CAT III 1000 V safety rating
Specially designed to offer maximum utility in a very compact shape
FLUKE 9040 Phase Rotation Indicator
3 phase indication
Indication of phase rotation
Clear LCD display
No battery required
Fluke 1587/MDT FC Specifications
AC Voltage Measurements
Range
600 mV
6 V
60 V
600 V
1000 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 5000 Hz ±(% of Rdg + counts)
±(2% + 3)
±(2% + 3)
±(2% + 3)
±(2% + 3)1
±(2% + 3)1
Low-Pass Filter Voltage
Range
600 mV
6 V
60 V
600 V
1000 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
50 to 60 Hz ±(% of Rdg + counts)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(1% + 3)
±(2% + 3)
60 to 400 Hz ±(% of Rdg + counts)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
±(2% + 3) – (6% – 3)
DC Voltage Measurement
Range
6 V dc
60 V dc
600 V dc
1000 V dc
Resolution
0.001 V
0.01 V
0.1 V
1 V
Accuracy ±(% of Rdg + Counts)
±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
±(0.09% + 2)
Input Impedance
10 MΩ (nominal), <100 pF
Nominal Mode Rejection Ratio
>60 dB at 50 or 60 Hz
Common Mode Rejection Ratio
>120 dB at dc, 50 or 60 Hz (1 k unbalance)
DC Millivolts Measurement
Range
600 mVdc
Resolution
0.1 mV
Accuracy ±(% of Rdg + Counts)
±(0.1 + 1)
DC and AC Current Measurement
Range
400 mA
Resolution
0.1 mA
Accuracy ±(% of Rdg+Counts)
±(1.5% + 2)1
Burden Voltage (Typical)
2 mV/mA
Range
60 mA
Resolution
0.01 mA
Accuracy ±(% of Rdg+Counts)
±(1.5% + 2)1
Burden Voltage (Typical)
2 mV/mA
DC
Range
400 mA
Resolution
0.1 mA
Accuracy ±(% of Rdg+Counts)
±(0.2% + 2)
Burden Voltage (Typical)
2 mV/mA
Range
60 mA
Resolution
0.01 mA
Accuracy ±(% of Rdg+Counts)
±(0.2% + 2)
Burden Voltage (Typical)
2 mV/mA
Overload
600 mA for 2 minutes maximum
Fuse Protection for mA Input
0.44 mA, 1000 V, IR 10 kA
AC Conversion
Inputs are ac-coupled and calibrated to the rms value of sine wave input
Ohms Measurement
Range
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
50 MΩ
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy +(% of Rdg+Counts)1
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(0.9% + 2)
±(1.5% + 3)
Overload Protection
1000 rms or dc
Open Circuit Test Voltage
<8 V dc
Short Circuit Current
<1.1 mA
Diode Test
Diode Test Indication
Display voltage drop: 0.6 V at1.0 mA nominal test current
Accuracy
±(2% + 3)
Continuity Test
Continuity Indication
Continuous audible tone for testresistance below 25 Ω and off above 100 Ω
Maximum reading: 1000 Ω
Open Circuit Voltage
<8.0 V
Short Circuit Current
1.0 mA typical
Overload Protection
1000 V rms
Response Time
>1 m sec
Frequency Measurement
Range
99.99 Hz
999.9 Hz
9.999 kHz
99.99 kHz
Resolution
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy ±(% of Rdg+Counts)
±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
±(0.1% + 1)
Frequency Counter Sensitivity
600.0 mV ac
V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 mV
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 150.0 mV
DC Trigger Levels¹ to 20 kHz2: NA
6.0 V
V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 1.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 1.5 V
DC Trigger Levels¹ to 20 kHz2: -400.0 mV and 2.5 V
60.0 V
V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 10.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: 36.0 V
DC Trigger Levels¹ to 20 kHz2: 1.2 V and 4.0 V
600.0 V
V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 100.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
1000.0 V
V ac Sensitivity (RMS Sine Wave)1 5 Hz to 20 kHz: 300.0 V
V ac Sensitivity (RMS Sine Wave)1 20 to 100 kHz: NA
DC Trigger Levels¹ to 20 kHz2: 12.0 V and 40.0 V
Capacitance
Range
1000 nF
10.00 µF
100.0 µF
9999 µF
Resolution
1 nF
0.01 µF
0.1 µF
1 µF
Accuracy ±(% of Rdg+Counts)
±(1.2% + 2)
±(1.2% + 2)
±(1.2% ± 90 counts)
±(1.2% ± 90 counts)
Temperature Measurement
Range
-40 to 998°F (-40 to 537°C)
Resolution
0.1°F (0.1°C)
Accuracy ±(% of Rdg+Counts)1
±(1% + 10 counts)
±(1% + 18 counts)
Insulation Specifications
Measurement Range
0.01 MΩ to 2 GΩ
Test Voltages
50, 100, 250, 500, 1000 V
Test Voltage Accuracy
20%, 0%
Short-Circuit Test Current
1 mA nominal
Auto Discharge
Discharge time <0.5 second for C=1 µF or less
Live Circuit Detection
Inhibit test if terminal voltage >30 V prior to initialization of test
Maximum Capacitive Load
Operable with up to 1 µF load
Output Voltage
50 V (0% to +20%)
Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 50.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 50 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
100 V (0% to +20%)
Display range: 0.01 to 6.00 MΩ
Resolution: 0.01 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
Display range: 6.0 to 100.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 100 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(3% + 5 counts)
250 V (0% to +20%)
Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 250 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
500 V (0% to +20%)
Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 500 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 500 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 250 kΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
1000 V (0% to +20%)
Display range: 0.1 to 60.0 MΩ
Resolution: 0.1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 60 to 600 MΩ
Resolution: 1 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(1.5% + 5 counts)
Display range: 0.6 to 2.0 GΩ
Resolution: 100 MΩ
Test current: 1 mA at 1 MΩ
Resistance accuracy ±(% of Rdg + Counts): ±(10% + 3 counts)
Click here for complete specifications on the Fluke 1587/MDT FC
Fluke 1587FC Insulation Multimeter
Ideal for troubleshooting and preventative maintenance, this insulation multimeter comes in a compact, handheld design, and features True RMS capabilities. Additionally, this tool is compatible with the Fluke Connect app, which allows the user to see and share measurement results wirelessly with their smartphone or tablet.
Fluke i400 AC Current Clamp, 400 A AC, CAT IV 600 V/CAT III 1000 V
Compatible with digital multimeters, this current clamp measures up to 400 A AC and features a 1 mA/A output that guarantees easy reading on your meter. In addition, this clamp provides precise current measurements without breaking electric circuits, helping you measure safely with industry-standard safety ratings.
Fluke 9040 Phase Rotation Indicator
Phase Rotation Indicator for industrial applications. The Fluke 9040 Phase Rotation Indicator is a portable handheld instrument designed to detect the rotary field of three-phase systems. With three test leads, this rugged tester easily determines a clockwise or counterclockwise direction.
What’s included with the Fluke 1587/MDT FC
1587 FC Insulation Multimeter
i400 Current Clamp
9040 Phase Rotation Indicator
Remote probe
Test leads
Alligator clips
K-type thermocouple
Hard case
User documentation
Two in one tools
Stand-alone tools
Insulation test features
1587 FC
1577
1503
1507
1550C
1555
Test voltages
50 V, 100Â V, 250Â V, 500Â V, 1000Â V
500 V, 1000Â V
500 V, 1000Â V
50 V, 100Â V, 250Â V, 500Â V, 1000Â V
250 V to 5000Â V
250 V to 10,000Â V
Insulation resistance range
0.01 MΩ to 2 GΩ
0.01 MΩ to 600 GΩ
0.01 MΩ to 2000 GΩ
0.01 MΩ to 10 GΩ
250 kΩ to 1 TΩ
250 kΩ to 2 TΩ
PI/DAR
Auto discharge
Timed ramp test (Breakdown)
Pass/fail comparison
Est. # of IRT tests
1000
1000
2000
2000
Various
Various
Voltage > 30 V warning
Memory
With Fluke Connect App
Remote test probe
Lo ohms/earth-bond continuity
200 mA source (10 mΩ resolution)
200 mA source (10 mΩ resolution)
Display
Digital LCD
Digital LCD
Digital LCD
Digital LCD
Digital LCD/ analog display
Digital LCD/ analog display
Hold/lock
Multimeter features
AC/DC volts
Note: Not all product features and specifications are listed in this table. For more complete information, see individual product data sheets.
Footnotes:
1. Function useful for checking connections and motor windings. Also useful for users who are required to perform earth-bond continuity measurements during installation testing.
2. Filter for variable-speed motor drive measurements.
Current
Resistance
Continuity beeper
Temperature (contact)
Lo-pass filter2
Capacitance
Diode test
Frequency
MIN/MAX
Other features
Backlight
Software
Fluke Connect compatible
FlukeView® Forms Basic
Fluke View® Forms Basic
Battery
4 AA (NEDA 15A or IEC LR6)
4 AA (NEDA 15A or IEC LR6)
4 AA (NEDA 15A or IEC LR6)
4 AA (NEDA 15A or IEC LR6)
Rechargeable
Rechargeable
Find out more about insulation testing
See it. Save it. Share it. All the facts, right in the field.
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Androidâ„¢ or iOS smart phone you already carry.
Fluke Connect with ShareLiveâ„¢ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products – the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Fluke Connect Features:
TrendItâ„¢ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
EquipmentLogâ„¢ History: Access equipment history building a database of equipment health and baselines with cloud backup.
ShareLiveâ„¢ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
AutoRecordâ„¢ Measurements: Instantly save measurements to your phone with Cloud backup.
Fluke Cloudâ„¢ Storage: Securely access equipment records anywhere, anytime.
Fluke Connect Benefits:
Maximize uptime
Minimize maintenance costs
Better assessments with accurate records
Higher efficiency with less walking around; no notebook and excel needed
Share troubleshooting knowledge live
Create and share helpful content in the field
Access to Fluke digital product manuals means no need to carry manuals in the field
Keep organized manually entered measurements
Why you need the Fluke 1587 FC Insulation Multimeter
Insulation multimeters are an integrated tool for maintaining and troubleshooting motor systems, electrical distribution, and production equipment. Carrying the Fluke 1587 FC will enable you to test insulation more often, making your maintenance tests more thorough and your troubleshooting more effective.
This multimeter combines a TRMS digital multimeter and a digital insulation tester in a single, compact unit. For this reason, it is capable of measuring a higher resistance than the average multimeter; allowing you to know when a cable is leaking under high voltage – see 0:25.
Its compatibility with Fluke Connect® makes it even more of an asset in your toolbox! Find out why at 0:58.
Fluke 1587 FC Tips and Tricks: Low-Pass Filter
Get step-by-step instructions on using a VFD drive and the 1587 FC. By connecting the unit to a smartphone or tablet via Bluetooth, you can see your measurements in current time.
How To Test a Motor with the Fluke 1587 FC Insulation Meter
Use the Fluke Connect App to save the measurements taken for a later date. To test a motor, follow the simple step-by-step instructions provided in the video. You’ll complete a motor test in no time at all.
How To Take Insulation Resistance Measurements with the Fluke 1587FC
This video will teach the viewers how to take insulation resistance measurements with this insulation multimeter. It also shows the viewers where functions that relate to insulation resistance are on the device. Additionally, this test instrument is Fluke Connect compatible.
There are no reviews yet.