Fluke 117 Offers
The digital multimeter includes integrated non-contact voltage detection to help get the job done faster
Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.
Engineered and tested with your safety on the job in mind
Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.
Features
VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30 seconds)
Resistance, continuity, frequency and capacitance
Min/max/average to record signal fluctuations
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
Accurate and easy-to-use
Provides low input impedance to help prevent false readings due to ghost voltage
CAT III 600 V safety rated
Applications
Commercial buildings
Hospitals
Schools
REED R5110 Non-Contact Voltage Detector with Flashlight
This Voltage Detector has the ability to detect the presence of AC voltage from a safe distance. The R5110 features two voltage ranges allowing it to detect both high (90 to 1000V) and low (24 to 1000V) AC voltage wiring.
Features
Suitable for receptacles or against insulated wire
Double insulated housing for increased safety
Audible (buzzer) and visual (LED) indicators
Built-in flashlight
Pocket clip
Auto shut off
Cat. IV 1000V safety ratingFluke 117 Offers
The digital multimeter includes integrated non-contact voltage detection to help get the job done faster
Ideal for applications such as commercial buildings, hospitals, and schools, this multimeter comes equipped with True-RMS. This instrument helps prevent false readings caused by ghost voltage due to integrated non-contact voltage detection, Auto Volts, and LoZ functions. Additionally, this tool comes supplied with min/max/average readings and measures frequency, capacitance, and an easy-to-use interface.
Engineered and tested with your safety on the job in mind
Tested for safe use in CAT III 600 V environments and designed in several features to make it easier and faster for you to get the measurements you need.
Features
VoltAlert™ technology for non-contact voltage detection
AutoVolt automatic ac/dc voltage selection
LoZ: helps prevent false readings due to ghost voltage
Large white LED backlight to work in poorly lit areas
True-rms for accurate measurements on non-linear loads
Measures 10 A (20 A overload for 30 seconds)
Resistance, continuity, frequency and capacitance
Min/max/average to record signal fluctuations
Compatible with optional magnetic hanger (ToolPak™) for hands free operation
Accurate and easy-to-use
Provides low input impedance to help prevent false readings due to ghost voltage
CAT III 600 V safety rated
Applications
Commercial buildings
Hospitals
Schools
REED R5110 Non-Contact Voltage Detector with Flashlight
This Voltage Detector has the ability to detect the presence of AC voltage from a safe distance. The R5110 features two voltage ranges allowing it to detect both high (90 to 1000V) and low (24 to 1000V) AC voltage wiring.
Features
Suitable for receptacles or against insulated wire
Double insulated housing for increased safety
Audible (buzzer) and visual (LED) indicators
Built-in flashlight
Pocket clip
Auto shut off
Cat. IV 1000V safety rating
Fluke 117/EFSP-KIT2 Specifications
DC millivolts
Range
600.0 mV
Resolution
0.1 mV
Accuracy
±0.5% of reading + 2 counts
DC Volts
Range
6.000 V
60.00 V
600.0 V
Resolution
0.001 V
0.01 V
0.1 V
Accuracy
±0.5% of reading + 2 counts
Auto Volts
Range
600 mV
Resolution
0.1 mV
Accuracy
2% + 3 (dc. 45 to 500 Hz)
4% + 3 (500 Hz to 1 kHz)
AC millivolts True RMS
Range
600.0 mV
Resolution
0.1 mV
Accuracy
45 to 500 Hz: ±1.0% of reading + 3 counts
500 Hz to 1 kHz: ±2.0% of reading + 3 counts
AC Volts True RMS
Range
6.000 V
60.00 V
600.0 V
Resolution
0.001 V
0.01 V
0.1 V
Accuracy
45 to 500 Hz: ±1.0% of reading + 3 counts
500 Hz to 1 kHz: ±2.0% of reading + 3 counts
Continuity
Range
600 Ω
Resolution
1 Ω
Accuracy
Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer
Ohms
Range
600 Ω
6 kΩ
60 kΩ
600 kΩ
6 MΩ
40 MΩ
Resolution
0.1 Ω
0.001 kΩ
0.01 kΩ
0.1 kΩ
0.001 MΩ
0.01 MΩ
Accuracy
0.9% + 1
Diode Test
Range
2 V
Resolution
0.001 V
Accuracy
0.9% + 2
Capacitance
Range
1000 nF
10 µF
100 µF
9999 µF
100 to 1000 µF
>1000 µF
Resolution
1 nF
0.01 µF
0.1 µF
1 µF
Accuracy
1.9% + 2
1.9% + 2
5% + 20
Lo-Z Capacitance
Range
1 nF to 500 µF
Accuracy
10% + 2 typical
AC Amps True RMS (45 to 500 Hz)
Range
6.000 A
10.00 A
20 A overload for 30 seconds maximum
Resolution
0.001 A
0.01 A
Accuracy
±1.5% of reading + 3 counts
AC µAmps True RMS (45 Hz to 1 kHz)
Range
600.0 µA
Resolution
0.1 µA
Accuracy
±1.5% of readings + 3 counts (±2.5% of readings + 3 counts >500 Hz)
DC Amps
Range
6.000 A
10.00 A
20 A overload for 30 seconds maximum
Resolution
0.001 A
0.01 A
Accuracy
±1.0% of readings + 3 counts
Hz (V or A input)
Range
99.99 Hz
999.9 Hz
9.999 kHz
50.00 kHz
Resolution
0.01 Hz
0.1 Hz
0.001 kHz
0.01 kHz
Accuracy
±0.1% of readings + 2 counts
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground
600 V
Surge Protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Fuse for A Input
11 A, 1000 V FAST Fuse (Fluke PN 803293)
Display
Digital: 6000 counts, updates 4/sec
Bar Graph
33 segments, updates 32/sec
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-40 to 140°F (-40 to 60°C)
Battery
9 V alkaline, NEDA 1604A/IEC 6LR61
Battery Life
400 hours typical, without backlight
Click here for complete specifications on the Fluke 117/EFSP-KIT2
The Fluke 117/EFSP Digital Multimeter Kit Includes
Fluke 117 Electrician’s Multimeter with non-contact voltage
Performs non-contact voltage detection and helps prevent false readings caused by ghost voltage with integrated VoltAlert technology, AutoVolts, and LoZ functions. Additionally, this multimeter is ideal for electricians and used for applications such as commercial buildings, hospitals, and schools.
REED R5110 Non-Contact Voltage Detector with Flashlight
AC Voltage Detector with built-in flashlight and pocket clip.
What’s included with the Fluke 117/EFSP-KIT2
Multimeter
Test Leads
Holster
9 V Battery
User Manual
Webinar: EVSE Safety Maintenance with Fluke
In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.
How To Determine if a Voltage is True or a Ghost Voltage Using the Fluke 117
This video will serve as a step by step tutorial on how to determine a real or ghost voltage with a digital multimeter with non-contact voltage. Additionally, it is ideal for demanding applications such as commercial buildings, hospitals, and schools.
There are no reviews yet.