Specifications
OVERVIEW
UPC Code | 037332179067 |
INPUT
Nominal Input Voltage(s) Supported | 220V AC; 230V AC; 240V AC |
Recommended Electrical Service | DC INPUT: Requires 48VDC input source capable of delivering 120A for the required duration (when used at full continuous capacity – DC requirements increase during OverPower and DoubleBoost operation). For automotive applications, professional hardwire |
Maximum Input Amps | 120 |
Input Connection Type | DC INPUT: Set of DC bolt-down terminals. AC INPUT: Hardwire via built in terminal strip with cover plate |
Voltage Compatibility (VAC) | 220; 230; 240 |
Voltage Compatibility (VDC) | 48 |
OUTPUT
Frequency Compatibility | 50 / 60 Hz |
Pure Sine Wave Output | Yes |
Output (Watts) | 4000 |
Nominal Output Voltage(s) Supported | 220V; 230V; 240V |
Output Receptacles | Hardwire |
Continuous Output Capacity (Watts) | 4000 |
Peak Output Capacity (Watts) | 8000 |
Output Voltage Regulation | LINE POWER (AC): Maintains nominal sine wave output from line power source. INVERTER POWER (AC): Maintains sine wave output of +/-2% |
Output Frequency Regulation | 50/60 Hz (+/- 0.5 Hz) |
BATTERY
Expandable Battery Runtime | Runtime is expandable with any number of user supplied wet or gel type batteries |
DC System Voltage (VDC) | 48 |
Battery Pack Accessory (Optional) | Â 98-121Â sealed lead acid battery (optional) |
Battery Charge | Selectable 1~70 amp charge rate |
USER INTERFACE, ALERTS & CONTROLS
Front Panel LEDs | LCD display offers continuous status information on load percentage (6 levels reported) and battery charge level (7 levels reported). See manual for sequences. |
Switches | 5 memebrane switches allow user to operate and configure unit operation. |
PHYSICAL
Material of Construction | Metal |
Cooling Method | Fan |
Shipping Dimensions (hwd / in.) | 11.80 x 12.50 x 31.00 |
Shipping Weight (lbs.) | 59.00 |
Unit Dimensions (hwd / in.) | 9 x 7.25 x 22.50 |
Unit Weight (lbs.) | 57 |
ENVIRONMENTAL
Relative Humidity | 0-95% non-condensing |
Operating Temperature | 32-104 Fahrenheit / 0-40 Celcius |
COMMUNICATIONS
Network Monitoring Port | ASNET (RJ45) ports provide RS-485 (MODBUS) communication for remote monitoring and management |
LINE / BATTERY TRANSFER
Transfer Time (Line Power to Battery Mode) | 20 millisecond (full cycle) / 10 millisecond (half-cycle) |
Low Voltage Transfer to Battery Power | In AC “auto” mode, inverter/charger switches to battery mode as line voltage drops 10 to 80V AC (user adjustable). See manual |
High Voltage Transfer to Battery Power | In AC “auto” mode, inverter/charger switches to battery mode as line voltage increases 10 to 40V AC (user adjustable). See manual |
FEATURES & SPECIFICATIONS
TVSS Grounding | Main grounding lug connects inverter/charger to earth or vehicle chassis ground |
WARRANTY & SUPPORT
Product Warranty Period (U.S. & Canada) | 2-year limited warranty |