Avionics Battery for lighting, standby, emergency power. Protects and extends the life of other avionics. Concorde’s Emergency Batteries float directly on the DC buss with no need for a dedicated charger. This results in a high inrush current which extends battery life with fast recovery time from discharge. With the battery floating directly on the buss, transient spikes in the DC power are absorbed. These batteries are self regulating on charge and will take only the current required to maintain it at full charge.
Test Temperature @ 23°C (74°F) = C1 is 2.0 Ah
Test Temperature @ -18°C (0°F) = C1 is 1.3 Ah
Test Temperature @ -30°C (-22°F) = C1 is 0.9 Ah
Recombinant Gas – The RG® Series are low resistance, valve regulated lead acid (VRLA) batteries.
Maintenance free
Constructed with non removable vent valves – no addition of electrolyte or water required
Aerobatic: Non spillable at any altitude or attitude
Factory tested to assure airworthiness
Shipped fully charged and ready to install
Manufactured with absorbed glass mat separators (AGM)
RG® Series batteries ship non-HAZMAT
Internal 115 VAC, 400 HZ Internal Charger
SpecificationsPrimary Aircraft Purpose: Emergency Aircraft BatteryVoltage: 24vRated Capacity C1 = 1 hr. rate in ampere hours: 2.00Max Weight: 6.80 lb / 3.1 kg
Documents  RG-140 Battery Outline Drawing (PDF)
  Click here to download BATTERY WARRANTY (PDF)  Click here to download FAA-PMA Installation Eligibility List PDF   Click here to download Storage and Boost Charge Recommendations PDF   Click here to download Concorde Battery AS9100 Certificate of RegistrationMaterial Safety Data Sheets (Click on link to download PDF)
  Lead Acid Batteries
  Dry Charged Batteries
There are no reviews yet.